Preclarifying bassin cover
|
Project |
Covers for preclarifying bassins, Stuttgart-Mühlhausen, Germany |
|
Client |
Provincial capital Stuttgart |
|
Structural and detailed design |
Peter und Lochner,
Beratende Ingenieure für Bauwesen GmbH |
|
Architects |
BED Bidlingmaier, Egenhofer, Dübbers, Stuttgart |
|
Description |
Three chord girder with cantilevers at each end
as supporting element for the suspended GRP-skin. The girders are
supported by columns, which are placed on the inner bassin wall.
Dimensions:
Girder width: 4,00 m
Span: 54 m und 42 m
Depth: 3,50 m |
|
Materials |
Structural steel S235 JR
|
|
Execution |
Leonhard Weiss, Göppingen
S.A.T., Altötting
C.F. Maier Kunstharzwerk, Königsbronn |
|